Features:
        • Fully Automatic to perform double cuff procedure as well as IVRA (Bier's Block) procedure.
        • The cuff pressure is always maintained to set value automatically.
        • Set value of cuff pressure can be altered to any other desired value even while it is in working mode.
        • Independent channel operation for Proximal as well as Distal side Cuff.
        • Parameter settings are independent of each other.
        • Can be operated with one Dual/Double cuff OR two Single separate cuffs with different pressures.
        • This Tourniquet can be programmed to suit your operation and post- operation needs by
              setting the parameters (DI) START DELAY & (ON) DURATION time.
        • Both the parameters START DELAY and ON time can be changed
               during the operation before it's individual execution.
        • Manual override for Cuff Deflation during programmed timing is also possible.
        • Sophisticated ALARMS to give better warning messages.
        • Independent ELAPSED TIME DISPLAY for both the channels.
        • Last settings remain in the MEMORY when power is turned off.
        • This Tourniquet is battery operated. hence PORTABLE and can be used anytime.
               anywhere even for post operation.
        • Built in battery charging circuit to re-charge the battery immediately by just connecting the power cord.
        • Colour coded cuffs and air tubing, specially designed, soft armored type
            cuffs to protect from accidental piercing by sharp tools.
        • Coiled, expandable, puncture resistant PU tubing with positive locking connectors (PLC)
        • The unit is compact, light weight, very small in size.

Specification :

  • Cuff Pressure : 100 to 500 mm of Hg with 2 mm of Hg resolution
  • Start Delay : 0 to 250 minutes setting
  • On/Duration Time : 0 to 250 minutes setting
  • Pressure Output Port : 2 ports having positive locking connectors (PLC)
  • Cuff Pressure Regulation : + / - 8 mm of Hg
  • Power : 6 volts DC battery ( built in battery charging circuit)
  • Operation Method : Micro-Controller based control
  • Elapes Time Diplay : Minutes : seconds
  • Tourniquet Cuff Types : 1 set od standard Dual Cuffs, 2 sets of three standard size single cuffs
  • Dimension : 185(W) X 95(H) X 170(D) mm