CR Bard StatLock PICC Plus Stabilization Device - PIC0220

MRP: Special Price ₹358
(per Count)
₹320
MRP: Regular Price ₹517
(per Count)

  • The StatLock® PICC Plus Stabilization Device offers great versatility and ease of use.
  • Combining the latest in design and engineering technology, StatLock® PICC Plus Stabilization Device releasably secures most winged–catheters on the market.
  • Just lift the transparents "gull-wings," place catheter wings over the posts, and close.
  • Anchor pad available in breathable, nonabsorbent tricot polyester or closed cell foam.
  • Sterile and latex-free.

FEATURES

 

StatLock® Stabilization Devices are a more effective alternative to tape in helping improve clinical outcomes, quality of care and economic efficiencies. The StatLock® PICC Plus Stabilization Device is a "post and door" design to house the suture wings of virtually all peripherally inserted central catheters (PICCs). Available in adult, pediatric and neonatal sizes.

The StatLock® PICC Plus Stabilization Device in a dressing change kit offers the StatLock® PICC Plus Stabilization Device with additional components including a mask, gloves, ChloraPrep™ Frepp™ solution, measuring tape, transparent dressing, gauze, alcohol pads, label, and adhesive strips. Another kit is available–for both PICC and CV dressing changes–which includes a drape, ChloraPrep™ One-Step and additional gauze. Now it's easier than ever to reap the clinical advantages of the StatLock® Stabilization Device with the ease of dressing change components in one package.

 

PRESCRIPTIVE INFORMATION

INDICATIONS FOR USE: The StatLock® stabilization device is compatible for medical tubes and catheters.

CONTRAINDICATIONS: Known tape or adhesive allergies. Known sensitivity to benzoin. (Zinc Oxide PICC Neonatal Universal)

WARNINGS AND PRECAUTIONS

  • Do not use the StatLock® stabilization device where loss of adherence could occur, such as with a confused patient, unattended access device, diaphoretic or non-adherent skin, or when the access device is not monitored daily.

  • Observe universal blood and body fluid precautions and infection control procedures, during the StatLock® stabilization device application and removal.

  • Suture the StatLock® stabilization device pad to skin if necessary or deemed necessary.

  • Avoid the StatLock® stabilization device contact with alcohol or acetone, both can weaken bonding of components and the StatLock® stabilization device pad adherence.

  • Minimize catheter manipulation during StatLock® stabilization device application and removal.

  • Remove oil and moisturizer from targeted skin area.

  • The StatLock® stabilization device pad adherence and catheter/tube position should be routinely inspected.

  • Orient the StatLock® stabilization device so arrows point toward the catheter tip.

  • The StatLock® stabilization device should be replaced every 7 days.

  • A StatLock® stabilization device luer-lock connector must be used to secure venous and arterial catheters.

  • Always apply the adhesive strip to central venous and arterial catheters at or near the insertion site when using a StatLock® stabilization device.

  • This is a single use device. Reuse/and or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patent.

  • Do not re-sterilize. The sterility of the single use device is not guaranteed following re-sterilization because of an indeterminable degree of potential pyrogenic or microbial contamination which may lead to infection complications. Re-sterilization may compromise the structural integrity, essential material and/or design characteristics and may lead to an unpredictable loss of functionality and/or device failure.

 

CLINICAL OUTCOMES

The Unrivaled Evidence You Need To Proceed

Clinical studies comparing the stabilization of catheter IVs using tape versus StatLock® stabilization devices demonstrate that StatLock® stabilization devices are unrivaled in helping to improve patient outcomes, quality of care and economic efficiencies.

The results demonstrate that the innovative designs of StatLock® stabilization devices provide superlative results in promoting healthcare worker safety and patient satisfaction. The comparative data makes a persuasive case as to why StatLock® stabilization devices are more effective than traditional forms of tape and suture stabilization to achieve the positive outcomes you seek.

Proven to Reduce Complications

StatLock® stabilization device for PICC and Central Line Catheter:

 

  • When a sterile securement device (StatLock® stabilization device) has been used routinely, total PICC complications and restarts in a hospital have decreased by 45%.
  • When compared to suture stabilization, StatLock® Stabilization Devices eliminate sharps injuries to health care workers when they are securing central catheter lines.

 

QUALITY OF CARE

The Unrivaled Evidence You Need To Proceed

Clinical studies comparing the stabilization of catheter using tape versus StatLock® stabilization devices demonstrate that the StatLock® stabilization devices are unrivaled in helping to improve patient outcomes, quality of care and economic efficiencies.

The results demonstrate that the innovative designs of StatLock® stabilization devices provide superlative results in promoting healthcare worker safety and patient satisfaction. The comparative data makes a persuasive case as to why StatLock® stabilization devices are more effective than traditional forms of tape and suture stabilization to achieve the positive outcomes you seek.

Enhances Patient Care

StatLock® stabilization device for PICC Catheter:

  • Meets the 2006 INS Standards that state "Whenever feasible, using a manufactured catheter stabilization device is preferred.
  • Eliminates suture related needlesticks.

 

 For more information on the product please refer the link below

 https://www.bardaccess.com/statlock-pcl-picc-plus.php?section=Overview

More Information
Brand Bard
Regulatory Approvals US FDA
Product Video
SKU BARD_DISP_STAT_PICC_STABDEV
Warranty

1 Year Warranty.